Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Imaging Technology ; (12): 1698-1701, 2019.
Article in Chinese | WPRIM | ID: wpr-861178

ABSTRACT

Objective: To explore the clinical value of prenatal ultrasound in diagnosis of vasa previa. Methods: The images of 65 230 pregnant women who underwent prenatal ultrasound examination were analyzed retrospectively. The accuracy of prenatal ultrasound in diagnosis of vasa previa was calculated. The delivery modes of all pregnant women and outcomes of all perinatal infants with vasa previa diagnosis were followed up. Results: Fifty-three vasa previa cases were diagnosed during the first examination using prenatal ultrasound and 10 cases were eliminated during reexamination in late pregnancy, so 43 cases were diagnosed. Finally 41 cases (41/65 230, 0.06%) were clinically confirmed. The accuracy of middle pregnancy screening (15-28 weeks) and late pregnancy (28-40 weeks) reexamination was 100%(28/28), and the accuracy of late pregnancy was 86.67%(13/15). Cesarean section surgery was performed in all 41 pregnant women, and all fetuses survived. Conclusion: Prenatal ultrasound has a high value of prenatal ultrasound in diagnosis of vasa previa.

2.
Chongqing Medicine ; (36): 475-477, 2017.
Article in Chinese | WPRIM | ID: wpr-510713

ABSTRACT

Objective To investigate the clinical value of prenatal ultrasound in fetal meningocele and encephalocele.Methods Thirty nine fetuses with meningocele and encephalocele confirmed by prenatal ultrasound and abortion were acquired and their clinical data and sonographic features were retrospectively analyzed.Results Ultrasound screening in 111 620 cases showed 39 fetuses were with meningocele and encephalocele,accounting for 0.35%.Among them,16 cases were diagnosed with meningocele (including 1 case with two bulging parts) and 23 cases with encephalocele.Prenatal ultrasound could clearly detect the location and size fetal skull defect,and bulging features.According to their sonographic features,meningocele or encephalocele was determined.Conclusion Ultrasound could be a reliable prenatal screening method,provide an important basis for clinical intervention and have a significant clinical value in fetal meningocele and encephalocele.

3.
Chinese Journal of Medical Imaging ; (12): 856-859, 2014.
Article in Chinese | WPRIM | ID: wpr-458427

ABSTRACT

PurposeTo explore the value of prenatal ultrasound in diagnosis of fetuses with limb body wall complex (LBWC).Material and MethodsThe ultrasound images and follow-up results were studied retrospectively in 20 cases of LBWC, and the ultrasonic features of LBWC were analyzed.ResultsAll 20 cases showed rather severe body wall defect and spinal abnormality, including 16 cases of abdominal wall defect, 4 cases of abdominal thoracoabdominal defect, 8 cases of idiopathic scoliosis, 2 cases of kyphosis, 3 cases of twist into a corner, 1 cases of distortion as S shape, and 6 cases of vertebral body arranged in disorder. Moreover, 16 cases presented abnormal umbilical cord,among which 11 had too short umbilical cord, 1 without umbilical cord, and 7 as single umbilical artery (3 cases with short cord). Five cases showed limb abnormalities, among which 2 cases were left lower limb absence, 1 cases as left upper limb absent, 1 cases as left foot varus and right foot slightly varus, and 1 cases as left foot drop.ConclusionPrenatal ultrasonography can accurately diagnose LBWC in time, so as to provide evidence for early clinical intervention.

4.
Chinese Journal of Ultrasonography ; (12): 41-43, 2011.
Article in Chinese | WPRIM | ID: wpr-384524

ABSTRACT

Objective To evaluate three dimensional fetal heart structure by sono-automatic volume count (SonoAVC) with spatio-temporal image correlation(STIC). Methods The heart volumes datas were acquired by STIC in 32 fetuses with postnatally confirmed diagnoses(20 cases of normal heart, 12 cases of complex congenital heart disease between 20 - 37 gestional weeks), then the volume datas were analyzed offline. SonoAVC software automaticly searched hypoechoic and anechoic structures, and assigned individual colors,and this can be corrected by manual splitting and/or removing and merging of individual segments.Results Individual segments of fetal heat could be separated,and digital casts were generated. The digital casts were obtained successfully in 4cases of transposition of the great arteries(TGA) ,2 cases of tetralogy of Follot,1 case of Ebstein's anomaly, 1 case of double-outlet right ventricle and 20 cases of normal heart.Conclusions Combination of STIC and SonoAVC can demonstrate the size, shape and connection of fetal cardiac cavities and great arteries in three dimensional spatial context. It has the potential both to help in obtaining strctural diagnostic,and to generate 3D visual displays for consultation and teaching.

5.
Chinese Journal of Ultrasonography ; (12): 996-999, 2011.
Article in Chinese | WPRIM | ID: wpr-423219

ABSTRACT

Objective To Study the effects of high mechanical index ultrasound radiation microbubble on colon cancer cell skeletal.Methods Lovo cell were cultured in vitro,and this study was divided into control group,simple contrast agent group,microbubble plus ultrasound radiation group and simple ultrasound radiation group.Ultrasound contrast agent SonoVue and ultransound (frequency 1.5 MHz and MI 1.7) were used.Results In the control group,the microtubes were densest in dyeing silk,and extended to the edge of a cell.In the ultrasound and microbubble group,the microtubes were weaker and thin,the.network was mainly in the structure of the long axis.The cells arranged in a slight pigmentation to the density cell,to reach out many fine short hair,there were obviously a sense of silk and directional.In the microbubble and ultrasound group,Lovo cells streamed of the central significantly reduced,fluorescent lighting,with short hair.There was no difference in the ultrasound group and the microbubble group with microfilament and microtubule.Conclusions High mechanical index ultrasound radiation can changed into vacant,a trace of the assembly and distributed to the tumor cells are attacking,the transfer of restraining.

6.
Chinese Journal of Ultrasonography ; (12): 517-520, 2010.
Article in Chinese | WPRIM | ID: wpr-388790

ABSTRACT

Objective To probe the diagnostic efficacy of fetal eehocardiography for characterizing complex congenital heart diseases.Methods Fetal echocardiography was performed on 49 cases of fetal complex congenital heart disease, the ultrasonic diagnosis was compared retrospectively with pathological results after autopsy.Results Antenatal sonographic diagnosis was in agreement with the pathological results in 42 cases (85.71 %), 7 cases were disagreed with pathological diagnosis (antenatal sonographic diagnosis was discrepancy in 3 cases, 4 cases were partially mis-classified).Twenty-four cases were combined with extra-cardiac malformations.Nine cases had chromosomal abnormality.Conclusions Fetal echocardiography is highly accurate for antenatal diagnosis of complex congenital heart disease, but it is hard to detect some type of cardiac anomalies.

7.
Chinese Journal of Ultrasonography ; (12): 430-433, 2008.
Article in Chinese | WPRIM | ID: wpr-400711

ABSTRACT

Objective To observe the effects of high mechanical index ultrasound contrast on hepatic metastasis of colorectal cancer. Methods Hepatic metastasis models were established by injecting Lovo cells into the spleen of SD rats.This study was divided into control group, microbubble plus ultrasound radiation group simple contrast agent group and simple ultrasound radiation group.Ultrasound contrast agent SonoVue(1 ml/kg) was injected via tail vein, high mechanical index ultrasound contrast (frequency 1.5 MHz,MI 1.7) was performed intermittently for 2 min.After 10 d,the animals were killed and the size and number of hepatic metastasis were compared.Histological pathology and its ultrastructure were observed.Results There were no significant differences between contral group,simple ultrasound radiation group and simple contrast agent group in metastatic rate ( P>0.05).There were no obvious differences between contral group, simple ultrasound radiation group and simple contrast agent group in cells'ultrastructure by transmission electron microscopy (TEM).The number and size of hepatic metastasis decreased obviously in microbabble plus ultrasound radiation group ( P<0.01 ), the mitochondrion was swelling and the gaps of endothelial cells were loose. Conclusions High mechanical index ultrasound contrast can inhibit the hepatic metastasis of colorectal cancer.

SELECTION OF CITATIONS
SEARCH DETAIL